YAMIT E.L.I.'s Media and Multi-Media Filters offer Quartz Sand, Volcanic Gravel, Anthracite, Catalytic Media and Active Carbon for a wide variety of applications and solutions. Applications include drinking water treatment, chemical disinfection, and pH and EC control.
Also among the media and multi-media filters applications is Iron Removal from water. This process includes pH control, oxidation with air, chlorine, or other oxidizing additives, and media filtration with deep sand media or catalytic media.
In YAMIT E.L.I.'s media and multi-media filters solutions, Volcanic Gravel ranges from sizes of 1-20mm.
Anthracite is used as a component of dual or multi-media filters for drinking water in conjunction with sand and possibly garnet. Catalytic media is used to remove catalytic iron and manganese from drinking water and Active Carbon is used to absorb chlorine and other minerals from water.
media and multi-media filters Diagram
| |
|
|
| |
|
| Legend: |
| 1. |
Upper Service Hole |
| 2. |
Filter Inlet |
| 3. |
Anthracite Layer |
| 4. |
Fine Sand Layer |
| 5. |
Coarse Sand Layer |
| 6. |
Filter Outlet |
| 7. |
Gravel Support Layer |
| 8. |
Filter Element |
| 9. |
Side Service Hole |
| |
|
| |
|
| |
|
| Legend: |
| 1. |
Upper Service Hole |
|
| 2. |
Upper Water Diffuser |
| 3. |
Drain |
| 4. |
Valve No. 1 |
| 5. |
Flocculent Dosing Pump |
| 6. |
Water Meter Electric |
| |
Output Signal |
| 7. |
Chlorine Dosing Pump |
| 8. |
SA500 Semi Automatic |
| |
Screen Filter |
| 9. |
Valve No. 4 |
| 10. |
Hydro Cyclone Static Mixer |
| 11. |
Valve No. 5 |
| 12. |
Raw Water Inlet Pump |
| 13. |
Valve No. 2 |
| 14. |
Filter Element |
| 15. |
Flush Water Pump |
| 16. |
Valve No. 3 |
| 17. |
Gravel, 1.2-0.8 mm |
| 18. |
Sand No. 1, 1.2-0.8 mm |
| 19. |
Sand No. 0, 1.2-0.8 mm |
| 20. |
Electric Control Panel |
| 21. |
Filter Body |
| 22. |
Air Valve |
YAMIT E.L.I. Media Filtration Systems- Steps and Components
pH control
Pre-disinfection
Dosing flocculants
Static mixers installed after each point of chemical injection
Slow media filtration in multi-media filters
Filter media is volcanic gravel, quartz sand, anthracite
Optional active carbon filtration
Optional filter backwash
Water quality monitoring for turbidity and disinfection
Automatic PLC control with dosing, filtration and pump control
ensuring precise, trouble-free, automatic operations.
Iron Removal Systems- Steps and Components
pH control
Oxidation with air, chlorine or other oxidizing additives
Media filtration with deep sand media or catalytic media
Filtration speed of 5 - 15 m/h
| 1.Chlorine Injection. |
6.Outside Source For Backwash. |
| 2.Free Chlorine Analyzer. |
7.Fore Wash. |
| 3.Coagulant Injection. |
8.Turbidity Metering. |
| 4.Static Mixer. |
9.Backwash. |
| 5.Static Mixer. |
10.Pump. |
|
Filter Model |
Connection Size |
Body Diameter |
Filtration Area
|
Recommended Flow Rate |
| M³/h |
L/sec |
gpm |
| Inch |
mm |
Inch |
mm |
SqM |
SqF |
Min |
Max
|
Min |
Max |
Min |
Max |
| F6020HM |
1.5 |
40 |
20 |
500 |
0.20 |
2.15 |
1 |
3 |
0.3 |
0.8 |
4.4 |
13.2 |
| F6025HM |
1.5 |
40 |
25 |
625 |
0.30 |
3.23 |
2 |
4 |
0.6 |
1.4 |
8.8 |
17.6 |
| F6030HM |
2 |
50 |
30 |
750 |
0.44 |
4.73 |
3 |
6 |
0.8 |
1.7 |
13.2 |
26.4 |
| F6036HM |
2 |
50 |
36 |
900 |
0.63 |
6.46 |
4 |
9 |
1.1 |
2.5 |
17.6 |
39.6 |
| F6048HM |
2 |
50 |
48 |
1200 |
1.13 |
12.16 |
6 |
17 |
1.7 |
4.7 |
26.4 |
74.9 |
| F6064HM |
3 |
80 |
64 |
1600 |
2.00 |
21.52 |
10 |
30 |
2.8 |
8.3 |
44.0 |
132.2 |
| F6080HM |
4 |
100 |
80 |
2000 |
3.14 |
33.79 |
16 |
47 |
4.5 |
13.0 |
70.5 |
207.0 |
| F6088HM |
4 |
100 |
88 |
2200 |
3.80 |
40.90 |
19 |
57 |
5.3 |
15.8 |
84.0 |
251.0 |
| F6100HM |
4 |
100 |
100 |
2500 |
4.90 |
52.70 |
25 |
74 |
6.9 |
20.5 |
110.0 |
326.0 |
| F6120HM |
6 |
150 |
120 |
3000 |
7.06 |
75.60 |
36 |
107 |
10.0 |
29.7 |
159.0 |
471.0 |
Top
|